{"product_id":"etherwan-sfp2im2am-2-5g-multimode-sfp","title":"EtherWAN SFP2IM2AM Hardened 2.5G Multimode SFP Module","description":"\n\u003cdiv class=\"cm-vendor-general\"\u003e\n\n  \u003c!-- STAT BAR --\u003e\n  \u003cdiv class=\"cm-stat-bar\"\u003e\n    \u003cdiv class=\"cm-stat-bar__item\"\u003e\n      \u003cdiv class=\"cm-stat-bar__value\"\u003e2.5 Gbps\u003c\/div\u003e\n      \u003cdiv class=\"cm-stat-bar__label\"\u003eEthernet Data Rate\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cm-stat-bar__item\"\u003e\n      \u003cdiv class=\"cm-stat-bar__value\"\u003e850 nm\u003c\/div\u003e\n      \u003cdiv class=\"cm-stat-bar__label\"\u003eOptical Wavelength\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cm-stat-bar__item\"\u003e\n      \u003cdiv class=\"cm-stat-bar__value\"\u003eDuplex LC\u003c\/div\u003e\n      \u003cdiv class=\"cm-stat-bar__label\"\u003eFiber Connector\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cm-stat-bar__item\"\u003e\n      \u003cdiv class=\"cm-stat-bar__value\"\u003e500 m\u003c\/div\u003e\n      \u003cdiv class=\"cm-stat-bar__label\"\u003eMaximum OM4 Reach\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cm-stat-bar__item\"\u003e\n      \u003cdiv class=\"cm-stat-bar__value\"\u003e-40 to +85°C\u003c\/div\u003e\n      \u003cdiv class=\"cm-stat-bar__label\"\u003eOperating Temperature\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- INTRO --\u003e\n  \u003cp class=\"cm-intro\"\u003e\n    The \u003cstrong\u003eEtherWAN SFP2IM2AM Hardened 2.5G Multimode SFP Transceiver\u003c\/strong\u003e delivers 2500 Mbps optical connectivity for compatible industrial Ethernet switches and networking equipment. Designed for 50\/125-micron multimode fiber, the module features 850 nm optics and a duplex LC connector, supporting distances up to 160 meters over OM2, 400 meters over OM3, and 500 meters over OM4 fiber. Digital Diagnostic Monitoring (DDM) provides transceiver monitoring capabilities through supported host equipment, while its hardened -40°C to +85°C temperature rating makes it suitable for industrial network installations requiring wide environmental tolerance.\n  \u003c\/p\u003e\n\n  \u003c!-- GEO FACTS --\u003e\n  \u003cp class=\"cm-intro\" id=\"cm-geo-facts\"\u003e\n    The EtherWAN SFP2IM2AM is a hardened 2.5G BASE Small Form-factor Pluggable (SFP) optical transceiver for multimode fiber networking. EtherWAN specifies a 2500 Mbps transmission speed, 850 nm wavelength, duplex LC connector, and 50\/125-micron multimode fiber compatibility. Maximum published distances are 160 m on OM2, 400 m on OM3, and 500 m on OM4. The manufacturer's optical specifications identify transmit power from -7.5 to -1 dBm and receiver sensitivity of -13.5 dBm, providing a calculated nominal optical power budget of 6 dB based on minimum transmit power. This calculated value is not presented as a confirmed manufacturer link-budget rating. The module supports DDM and operates from -40°C to +85°C. EtherWAN lists SFP2IM2AM as an accessory for selected EX61900G, EX71900G, and EX78900G switch series. The SFP Series specifications also identify a +3.3V power supply, SFP Multi-Source Agreement compliance, Class 1 laser safety, and RoHS compliance. Actual link performance depends on the fiber grade, optical attenuation, connectors, splices, compatible transceivers, and host equipment.\n  \u003c\/p\u003e\n\n  \u003c!-- HERO IMAGE --\u003e\n  \u003c!--\n    A verified Shopify CDN image for SFP2IM2AM is required.\n    The previously supplied product image appears to show\n    a 1.25G \/ 550m SFP, not this 2.5G module.\n    Do not use that image until the SKU is confirmed.\n  --\u003e\n\n  \u003c!-- KEY FEATURES --\u003e\n  \u003cdiv class=\"cm-section-label\"\u003e\n    \u003cdiv class=\"cm-section-label__bar\"\u003e\u003c\/div\u003e\n    \u003cspan class=\"cm-section-label__text\"\u003eKey Features\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cm-feature-grid cm-feature-grid--2col\"\u003e\n\n    \u003cdiv class=\"cm-feature-box\"\u003e\n      \u003ch3 class=\"cm-feature-box__title\"\u003e\n        2.5 Gbps Optical Ethernet Connectivity\n      \u003c\/h3\u003e\n      \u003cp class=\"cm-feature-box__text\"\u003e\n        The SFP2IM2AM supports optical transmission at 2500 Mbps for compatible 2.5 Gigabit Ethernet networking equipment. Its SFP form factor provides a modular fiber interface for supported industrial switches and network devices. Unlike a conventional 1 Gbps SFP transceiver, this model requires a host port that explicitly supports 2.5G operation and the applicable module configuration.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-feature-box\"\u003e\n      \u003ch3 class=\"cm-feature-box__title\"\u003e\n        850 nm Multimode Fiber Optics\n      \u003c\/h3\u003e\n      \u003cp class=\"cm-feature-box__text\"\u003e\n        The module operates at an 850 nm optical wavelength over 50\/125-micron multimode fiber. Its optical characteristics are intended for compatible OM2, OM3, and OM4 installations rather than long-distance single-mode links. The transceiver at the opposite endpoint must support the required speed, wavelength, fiber type, and optical power characteristics.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-feature-box\"\u003e\n      \u003ch3 class=\"cm-feature-box__title\"\u003e\n        Fiber Reach up to 500 Meters on OM4\n      \u003c\/h3\u003e\n      \u003cp class=\"cm-feature-box__text\"\u003e\n        EtherWAN publishes three maximum distances based on the installed multimode fiber grade: 160 meters on OM2, 400 meters on OM3, and 500 meters on OM4. These ratings allow network engineers to select the appropriate fiber infrastructure for the required connection. Actual reach must also account for installed cable quality, connector losses, splices, and optical operating margin.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-feature-box\"\u003e\n      \u003ch3 class=\"cm-feature-box__title\"\u003e\n        Duplex LC Optical Interface\n      \u003c\/h3\u003e\n      \u003cp class=\"cm-feature-box__text\"\u003e\n        The SFP2IM2AM uses a duplex LC connector with separate transmit and receive fiber paths. This two-fiber arrangement allows the module to connect through suitable multimode LC patch cords. Verify fiber polarity, connector condition, optical interface compatibility, and the installed cable grade before commissioning the link.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-feature-box\"\u003e\n      \u003ch3 class=\"cm-feature-box__title\"\u003e\n        Digital Diagnostic Monitoring Support\n      \u003c\/h3\u003e\n      \u003cp class=\"cm-feature-box__text\"\u003e\n        EtherWAN identifies Digital Diagnostic Monitoring (DDM) as a supported feature of the SFP2IM2AM. When connected to compatible host equipment, diagnostic information can help technicians assess optical transceiver operating conditions and investigate fiber connectivity problems. Available readings and management functions depend on the host switch and its monitoring capabilities.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-feature-box\"\u003e\n      \u003ch3 class=\"cm-feature-box__title\"\u003e\n        Hardened -40°C to +85°C Operation\n      \u003c\/h3\u003e\n      \u003cp class=\"cm-feature-box__text\"\u003e\n        The module supports an industrial operating temperature range from -40°C to +85°C, making it relevant for compatible networking installations exposed to demanding thermal conditions. Its hardened rating does not extend the operating limits of the connected switch, enclosure, cabling, or other components. The complete network installation must remain within the specifications of every device.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- REAL-WORLD APPLICATIONS --\u003e\n  \u003cdiv class=\"cm-section-label\"\u003e\n    \u003cdiv class=\"cm-section-label__bar\"\u003e\u003c\/div\u003e\n    \u003cspan class=\"cm-section-label__text\"\u003eReal-World Applications\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cm-audience-grid\"\u003e\n\n    \u003cdiv class=\"cm-audience-card\"\u003e\n      \u003cp class=\"cm-audience-card__label\"\u003e\n        Industrial Network Engineers\n      \u003c\/p\u003e\n      \u003cp class=\"cm-audience-card__text\"\u003e\n        Deploy compatible 2.5 Gigabit fiber connections between industrial Ethernet switches using multimode cabling and hardened optical transceivers.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-audience-card\"\u003e\n      \u003cp class=\"cm-audience-card__label\"\u003e\n        Fiber Infrastructure Integrators\n      \u003c\/p\u003e\n      \u003cp class=\"cm-audience-card__text\"\u003e\n        Design OM2, OM3, and OM4 fiber links while matching the required distance, 850 nm wavelength, duplex LC interface, and optical operating limits.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-audience-card\"\u003e\n      \u003cp class=\"cm-audience-card__label\"\u003e\n        Industrial Automation Teams\n      \u003c\/p\u003e\n      \u003cp class=\"cm-audience-card__text\"\u003e\n        Connect supported networking equipment in manufacturing facilities where fiber connectivity and wide operating temperature tolerance are required.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-audience-card\"\u003e\n      \u003cp class=\"cm-audience-card__label\"\u003e\n        Professional AV Network Integrators\n      \u003c\/p\u003e\n      \u003cp class=\"cm-audience-card__text\"\u003e\n        Evaluate compatible 2.5GbE multimode fiber links for equipment management, network infrastructure, and supported professional AV applications.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-audience-card\"\u003e\n      \u003cp class=\"cm-audience-card__label\"\u003e\n        Campus and Facility IT Teams\n      \u003c\/p\u003e\n      \u003cp class=\"cm-audience-card__text\"\u003e\n        Plan fiber connectivity between equipment rooms, distribution points, and nearby buildings where supported 2.5G ports and multimode infrastructure are available.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-audience-card\"\u003e\n      \u003cp class=\"cm-audience-card__label\"\u003e\n        Network Maintenance Technicians\n      \u003c\/p\u003e\n      \u003cp class=\"cm-audience-card__text\"\u003e\n        Identify the correct 850 nm hardened 2.5G SFP for compatible fiber-link replacement, diagnostic monitoring, and network maintenance.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003cdiv class=\"cm-section-label\"\u003e\n    \u003cdiv class=\"cm-section-label__bar\"\u003e\u003c\/div\u003e\n    \u003cspan class=\"cm-section-label__text\"\u003e\n      Hardened 2.5G Multimode SFP Technical Specifications\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cm-table-wrap\"\u003e\n    \u003ctable class=\"cm-table\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n          \u003cth scope=\"col\"\u003eDetail\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eEtherWAN\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eSFP2IM2AM\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eHardened 2.5G Multimode SFP Module (850 nm, Duplex LC, DDM)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eFiber Optic Transceivers and Networking Modules\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eHardened 2.5 Gigabit Multimode Optical SFP Transceiver\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eModule Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eSmall Form-factor Pluggable (SFP)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eManufacturer Series\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e2.5G BASE SFP Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e2500 Mbps \/ 2.5 Gbps\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eOptical Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e850 nm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eOptical Fiber Type\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eMultimode Fiber (MMF)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eFiber Core \/ Cladding\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e50\/125 microns\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eSupported Fiber Grades\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eOM2, OM3, and OM4 Multimode Fiber\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eMaximum OM2 Fiber Distance\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e160 m \/ Approximately 525 ft\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eMaximum OM3 Fiber Distance\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e400 m \/ Approximately 1,312 ft\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eMaximum OM4 Fiber Distance\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e500 m \/ Approximately 1,640 ft\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eDuplex LC\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eFiber Configuration\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eDuplex \/ Two-Fiber Optical Connection\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eOptical Output Power\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e-7.5 to -1 dBm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eReceiver Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e-13.5 dBm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eCalculated Nominal Optical Power Budget\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e6 dB, derived from minimum TX power of -7.5 dBm and receiver sensitivity of -13.5 dBm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eManufacturer-Published Link Budget\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eA separate numerical value is not clearly identified in the reviewed manufacturer table\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eDigital Diagnostic Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eSupported (DDM)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eDDM Host Requirement\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eCompatible networking equipment with transceiver diagnostic monitoring support\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e-40°C to +85°C \/ -40°F to +185°F\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eTemperature Classification\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eHardened \/ Industrial\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eElectrical Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eSingle +3.3V, per EtherWAN SFP Series specifications\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eHot-Pluggable Design\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eSFP Series feature; follow the host equipment installation instructions\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eSFP Interface Compliance\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eMulti-Source Agreement (MSA)\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eLaser Safety\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eClass 1, EN 60825-1, per EtherWAN SFP Series specifications\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eEnvironmental Compliance\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eRoHS Compliant, Lead-Free\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eEMC Compliance\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eFCC Part 15 and CENELEC EN 55022, per manufacturer series specifications\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eEtherWAN EX61900G Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eManufacturer-listed SFP accessory; verify exact switch variant and port configuration\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eEtherWAN EX71900G Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eManufacturer-listed SFP accessory; verify exact switch variant and port configuration\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eEtherWAN EX78900G Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eManufacturer-listed SFP accessory; verify exact switch variant and port configuration\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eOther Host Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eRequires confirmation with the networking equipment manufacturer\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eHost Interface Requirement\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eSupported SFP Port Capable of 2500 Mbps Optical Operation\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eRemote Transceiver Requirement\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eCompatible 2.5G Multimode Duplex Optical Transceiver with Suitable 850 nm Characteristics\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eSingle-Mode Fiber Support\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eNot the Specified Fiber Type; Designed for Multimode Fiber\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eSingle-Fiber BiDi Support\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eNo; Uses Separate Transmit and Receive Fiber Strands\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003e10 Gigabit Ethernet Support\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eNot a 10G SFP+ Transceiver\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eRelated Single-Mode Model\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eEtherWAN SFP2IS20M, a separate 1310 nm 2.5G Single-Mode SFP rated for 20 km\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eFiber Link Planning\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eVerify Fiber Grade, Optical Loss, Connector and Splice Losses, Endpoint Compatibility, and Engineering Margin\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eModel-Specific Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eNot confirmed in reviewed manufacturer specifications\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eModel-Specific Weight\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eNot confirmed in reviewed manufacturer specifications\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eExact package contents not confirmed; remote transceiver and fiber cabling must be selected separately\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eManufacturer Warranty\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eSubject to EtherWAN's applicable product warranty policy and purchase terms\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- FREQUENTLY ASKED QUESTIONS --\u003e\n  \u003cdiv class=\"cm-section-label\"\u003e\n    \u003cdiv class=\"cm-section-label__bar\"\u003e\u003c\/div\u003e\n    \u003cspan class=\"cm-section-label__text\"\u003eFrequently Asked Questions\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003e\n        What is the EtherWAN SFP2IM2AM used for?\n      \u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003e\n          The EtherWAN SFP2IM2AM is a hardened 2.5 Gigabit Ethernet multimode SFP transceiver designed for compatible networking equipment. It uses 850 nm optics and a duplex LC connector to establish optical connections over supported OM2, OM3, or OM4 multimode fiber. It also supports Digital Diagnostic Monitoring.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003e\n        What is the maximum fiber distance of the SFP2IM2AM?\n      \u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003e\n          EtherWAN rates the SFP2IM2AM for distances up to 160 meters on OM2, 400 meters on OM3, and 500 meters on OM4 multimode fiber. The applicable maximum depends on the installed fiber grade. Actual link performance also depends on optical attenuation, connectors, splices, and the complete connection design.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003e\n        Which fiber type and connector does the EtherWAN SFP2IM2AM require?\n      \u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003e\n          The SFP2IM2AM uses 50\/125-micron multimode fiber with a duplex LC connector. EtherWAN specifies OM2, OM3, and OM4 fiber grades for different maximum distances. Its optical interface uses separate transmit and receive fiber strands rather than the single-fiber arrangement used by BiDi transceivers.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003e\n        Does the EtherWAN SFP2IM2AM support DDM and hardened temperatures?\n      \u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003e\n          Yes. EtherWAN lists Digital Diagnostic Monitoring support and an operating temperature range from -40°C to +85°C. DDM readings depend on host equipment support. The complete installation must also satisfy the environmental specifications of the connected network switch, enclosure, and other components.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003e\n        What are the optical transmit power and receiver sensitivity specifications?\n      \u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003e\n          EtherWAN specifies optical transmit power from -7.5 to -1 dBm and receiver sensitivity of -13.5 dBm. Using minimum transmit power, the calculated nominal optical power budget is 6 dB. This is a derived value rather than a clearly stated manufacturer link-budget rating. Engineers should also account for receiver input limits and suitable operating margin when designing the fiber connection.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003e\n        Which EtherWAN switches list SFP2IM2AM as an accessory?\n      \u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003e\n          EtherWAN lists SFP2IM2AM among its SFP accessories for the EX61900G, EX71900G, and EX78900G switch series. The exact switch variant, port speed, supported module list, and firmware requirements should be confirmed before installation. Compatibility with other equipment is not automatically guaranteed.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003e\n        What is the difference between SFP2IM2AM and SFP2IS20M?\n      \u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003e\n          The SFP2IM2AM is a hardened 850 nm multimode SFP designed for distances up to 500 meters on OM4 fiber. The SFP2IS20M is a separate hardened 1310 nm single-mode SFP rated for distances up to 20 kilometers. Both use duplex LC connectors and support 2.5 Gbps transmission with DDM, but their optical wavelengths and fiber requirements are different.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- CALL TO ACTION --\u003e\n  \u003cdiv class=\"cm-cta\"\u003e\n    \u003ch3 class=\"cm-cta__title\"\u003e\n      Need the EtherWAN SFP2IM2AM Hardened 2.5G SFP?\n    \u003c\/h3\u003e\n    \u003cp class=\"cm-cta__text\"\u003e\n      Contact Coremicro to confirm compatibility with your EtherWAN EX61900G, EX71900G, EX78900G, or other supported networking equipment. Our team can help review 2.5GbE optical interface requirements, OM2\/OM3\/OM4 fiber grades, 850 nm duplex LC connectivity, DDM support, product availability, and purchasing options for your network installation.\n    \u003c\/p\u003e\n    \u003ca href=\"\/pages\/contact\" class=\"cm-cta__button\"\u003e\n      Talk to a Specialist\n    \u003c\/a\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- FOOTER LINKS --\u003e\n  \u003cdiv class=\"cm-footer-links\"\u003e\n    \u003cp class=\"cm-footer-links__label\"\u003eContinue Exploring\u003c\/p\u003e\n    \u003cdiv class=\"cm-footer-links__list\"\u003e\n      \u003ca href=\"https:\/\/www.etherwan.com\/us\/products\/sfp-fiber-transceiver\" class=\"cm-footer-links__item cm-footer-links__item--primary\"\u003e\n        EtherWAN SFP Specifications\n      \u003c\/a\u003e\n      \u003ca href=\"\/products\/etherwan-sfp2is20m-2-5g-single-mode-sfp\" class=\"cm-footer-links__item\"\u003e\n        Related Single-Mode SFP\n      \u003c\/a\u003e\n      \u003ca href=\"\/pages\/contact\" class=\"cm-footer-links__item\"\u003e\n        Contact Coremicro\n      \u003c\/a\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n","brand":"EtherWan","offers":[{"title":"Default Title","offer_id":47488739410082,"sku":"EtherWan-SFP2IM2AM","price":317.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/0860\/0738\/files\/EtherWan-SFP2IM2AM.webp?v=1792993303","url":"https:\/\/www.coremicro.com\/products\/etherwan-sfp2im2am-2-5g-multimode-sfp","provider":"COREMICRO.COM","version":"1.0","type":"link"}