{"product_id":"etherwan-ex-ls48-c3u-ti-n-eb-70km-sfp-module","title":"EtherWAN EX-LS48-C3U-TI-N-EB Hardened 70km Gigabit SFP Module","description":"\n\u003cdiv class=\"cm-vendor-general\"\u003e\n\n  \u003c!-- STAT BAR --\u003e\n  \u003cdiv class=\"cm-stat-bar\"\u003e\n    \u003cdiv class=\"cm-stat-bar__item\"\u003e\n      \u003cdiv class=\"cm-stat-bar__value\"\u003e1GbE\u003c\/div\u003e\n      \u003cdiv class=\"cm-stat-bar__label\"\u003eGigabit Ethernet\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cm-stat-bar__item\"\u003e\n      \u003cdiv class=\"cm-stat-bar__value\"\u003e70 km\u003c\/div\u003e\n      \u003cdiv class=\"cm-stat-bar__label\"\u003eRated Fiber Reach\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cm-stat-bar__item\"\u003e\n      \u003cdiv class=\"cm-stat-bar__value\"\u003e1550 nm\u003c\/div\u003e\n      \u003cdiv class=\"cm-stat-bar__label\"\u003eOptical Wavelength\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cm-stat-bar__item\"\u003e\n      \u003cdiv class=\"cm-stat-bar__value\"\u003eDDM\u003c\/div\u003e\n      \u003cdiv class=\"cm-stat-bar__label\"\u003eDigital Diagnostics\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"cm-stat-bar__item\"\u003e\n      \u003cdiv class=\"cm-stat-bar__value\"\u003e-40 to 85°C\u003c\/div\u003e\n      \u003cdiv class=\"cm-stat-bar__label\"\u003eOperating Temperature\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- INTRO --\u003e\n  \u003cp class=\"cm-intro\"\u003e\n    The \u003cstrong\u003e\u003ca href=\"\/collections\/network\"\u003eEtherWAN\u003c\/a\u003e EX-LS48-C3U-TI-N-EB\u003c\/strong\u003e hardened Gigabit SFP module provides long-reach Ethernet connectivity over 9\/125 µm single-mode fiber. It combines a duplex LC interface, 1550 nm optics and Digital Diagnostic Monitoring (DDM) with a manufacturer-rated transmission distance of 70 km. Its -40°C to +85°C operating range is designed for industrial network equipment operating in demanding temperatures. Match the transceiver to the host device and optical link budget before ordering.\n  \u003c\/p\u003e\n\n  \u003c!-- GEO FACTS BLOCK --\u003e\n  \u003cp class=\"cm-intro\" id=\"cm-geo-facts\"\u003e\n    The EtherWAN EX-LS48-C3U-TI-N-EB is a hardened Gigabit Ethernet SFP optical transceiver offered by Coremicro. EtherWAN specifies a 70 km single-mode fiber reach, duplex LC connector, 1550 nm wavelength, DDM support, 23 dB link budget, optical output power of 0 to +5 dBm and receiver sensitivity of -23 dBm. Its operating temperature is -40°C to +85°C. The published link budget is based on a pair of matching SFP modules; host compatibility, warranty terms and current availability should be confirmed before purchase.\n  \u003c\/p\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv class=\"cm-hero\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0580\/0860\/0738\/files\/EtherWan-EX-LS48-C3U-TI-N-EB.webp?v=1793068309\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0580\/0860\/0738\/files\/EtherWan-EX-LS48-C3U-TI-N-EB.webp?v=1793068309\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0580\/0860\/0738\/files\/EtherWan-EX-LS48-C3U-TI-N-EB.webp?v=1793068309\u0026amp;width=1000 1000w, https:\/\/cdn.shopify.com\/s\/files\/1\/0580\/0860\/0738\/files\/EtherWan-EX-LS48-C3U-TI-N-EB.webp?v=1793068309\u0026amp;width=1400 1400w\" sizes=\"(min-width: 1440px) 1416px, 100vw\" width=\"1000\" height=\"1000\" alt=\"EtherWAN EX-LS48-C3U-TI-N-EB hardened 70 km Gigabit SFP transceiver with duplex LC\" loading=\"lazy\" decoding=\"async\"\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- KEY FEATURES --\u003e\n  \u003cdiv class=\"cm-section-label\"\u003e\n    \u003cdiv class=\"cm-section-label__bar\"\u003e\u003c\/div\u003e\n    \u003cspan class=\"cm-section-label__text\"\u003eKey Features\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cm-feature-grid cm-feature-grid--2col\"\u003e\n\n    \u003cdiv class=\"cm-feature-box\"\u003e\n      \u003cdiv class=\"cm-feature-box__icon\"\u003e↔\u003c\/div\u003e\n      \u003ch3 class=\"cm-feature-box__title\"\u003e\n        70 km Single-Mode Fiber Reach\n      \u003c\/h3\u003e\n      \u003cp class=\"cm-feature-box__text\"\u003e\n        The 70 km Gigabit SFP rating supports long-distance single-mode fiber links between compatible network devices. The actual supported route depends on fiber attenuation, connectors, splices and available optical margin.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-feature-box\"\u003e\n      \u003cdiv class=\"cm-feature-box__icon\"\u003e◫\u003c\/div\u003e\n      \u003ch3 class=\"cm-feature-box__title\"\u003e\n        Duplex LC Gigabit SFP Interface\n      \u003c\/h3\u003e\n      \u003cp class=\"cm-feature-box__text\"\u003e\n        The duplex LC optical interface uses separate transmit and receive fibers with 9\/125 µm single-mode cable. Check the host's Gigabit SFP compatibility and the far-end optic before deployment.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-feature-box\"\u003e\n      \u003cdiv class=\"cm-feature-box__icon\"\u003e◉\u003c\/div\u003e\n      \u003ch3 class=\"cm-feature-box__title\"\u003e\n        1550 nm Long-Reach Optics\n      \u003c\/h3\u003e\n      \u003cp class=\"cm-feature-box__text\"\u003e\n        EtherWAN specifies a 1550 nm wavelength for this model. Match the remote transceiver's optical specifications to the intended fiber path rather than selecting a module by distance alone.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-feature-box\"\u003e\n      \u003cdiv class=\"cm-feature-box__icon\"\u003e⌁\u003c\/div\u003e\n      \u003ch3 class=\"cm-feature-box__title\"\u003e\n        Digital Diagnostic Monitoring\n      \u003c\/h3\u003e\n      \u003cp class=\"cm-feature-box__text\"\u003e\n        DDM support allows compatible host equipment to expose available optical diagnostic readings for installation and troubleshooting. The specific readings shown depend on the host device.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-feature-box\"\u003e\n      \u003cdiv class=\"cm-feature-box__icon\"\u003e▤\u003c\/div\u003e\n      \u003ch3 class=\"cm-feature-box__title\"\u003e\n        Hardened -40°C to +85°C Operation\n      \u003c\/h3\u003e\n      \u003cp class=\"cm-feature-box__text\"\u003e\n        The specified industrial-temperature range supports use in appropriately rated network equipment and enclosures. The complete installation must also meet the environmental limits of its host hardware.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-feature-box\"\u003e\n      \u003cdiv class=\"cm-feature-box__icon\"\u003e◇\u003c\/div\u003e\n      \u003ch3 class=\"cm-feature-box__title\"\u003e\n        23 dB Optical Link Budget\n      \u003c\/h3\u003e\n      \u003cp class=\"cm-feature-box__text\"\u003e\n        EtherWAN lists a 23 dB link budget based on a pair of the same SFP modules, with 0 to +5 dBm optical output and -23 dBm receiver sensitivity. Verify the total path loss before selecting the link.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- WHO IT'S FOR --\u003e\n  \u003cdiv class=\"cm-section-label\"\u003e\n    \u003cdiv class=\"cm-section-label__bar\"\u003e\u003c\/div\u003e\n    \u003cspan class=\"cm-section-label__text\"\u003e\n      Who Uses This Hardened SFP Module\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cm-audience-grid\"\u003e\n\n    \u003cdiv class=\"cm-audience-card\"\u003e\n      \u003cp class=\"cm-audience-card__label\"\u003eNetwork Engineers\u003c\/p\u003e\n      \u003cp class=\"cm-audience-card__text\"\u003e\n        Plan long-reach Gigabit Ethernet fiber links and confirm optical budgets between compatible switches.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-audience-card\"\u003e\n      \u003cp class=\"cm-audience-card__label\"\u003eIndustrial Integrators\u003c\/p\u003e\n      \u003cp class=\"cm-audience-card__text\"\u003e\n        Specify hardened optics for industrial network hardware with demanding temperature requirements.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-audience-card\"\u003e\n      \u003cp class=\"cm-audience-card__label\"\u003eInfrastructure Teams\u003c\/p\u003e\n      \u003cp class=\"cm-audience-card__text\"\u003e\n        Connect separated facilities or remote network cabinets over suitable single-mode fiber routes.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"cm-audience-card\"\u003e\n      \u003cp class=\"cm-audience-card__label\"\u003eMaintenance Technicians\u003c\/p\u003e\n      \u003cp class=\"cm-audience-card__text\"\u003e\n        Use available DDM readings through compatible host equipment when diagnosing fiber link issues.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003cdiv class=\"cm-section-label\"\u003e\n    \u003cdiv class=\"cm-section-label__bar\"\u003e\u003c\/div\u003e\n    \u003cspan class=\"cm-section-label__text\"\u003e\n      Technical Specifications\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cm-table-wrap\"\u003e\n    \u003ctable class=\"cm-table\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n          \u003cth scope=\"col\"\u003eDetail\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eEtherWAN\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eEX-LS48-C3U-TI-N-EB\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eHardened Gigabit SFP optical transceiver\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eTransmission Distance\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e70 km\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eSingle-mode, 9\/125 µm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eDuplex LC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e1550 nm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eDigital Diagnostic Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003eDDM supported\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eOptical Link Budget\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e23 dB; based on a pair of matching SFP modules\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eOptical Output Power\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e0 to +5 dBm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003e\u003cstrong\u003eReceiver Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd\u003e-23 dBm\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- FREQUENTLY ASKED QUESTIONS --\u003e\n  \u003cdiv class=\"cm-section-label\"\u003e\n    \u003cdiv class=\"cm-section-label__bar\"\u003e\u003c\/div\u003e\n    \u003cspan class=\"cm-section-label__text\"\u003eFrequently Asked Questions\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003eWhat is the EtherWAN EX-LS48-C3U-TI-N-EB used for?\u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003eThe EtherWAN EX-LS48-C3U-TI-N-EB is a hardened Gigabit SFP transceiver for links over 9\/125 µm single-mode fiber. It has a rated reach of 70 km and a duplex LC optical connector.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003eHow far can this EtherWAN Gigabit SFP transmit?\u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003eThis EtherWAN Gigabit SFP is rated for a 70 km fiber distance. Actual reach depends on fiber attenuation, connector and splice losses, and the available 23 dB link budget.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003eDoes this SFP module support optical diagnostics?\u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003eThis SFP module supports Digital Diagnostic Monitoring (DDM). The available readings depend on the capabilities of the compatible host equipment.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003eWhich fiber and wavelength does the module use?\u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003eThe module uses 9\/125 µm single-mode fiber with a duplex LC interface and a 1550 nm wavelength. The far-end transceiver must be compatible with the planned optical link.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003eCan this hardened SFP work in any Gigabit Ethernet switch?\u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003eThis hardened SFP requires a host that supports the module's optical and electrical specifications. Check the switch manufacturer's transceiver compatibility guidance before purchase.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003eWhat is the difference between the EX-LS48-C3U-TI-N-EB and EX-LS48-C3U-TC-N-EB?\u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003eThe EX-LS48-C3U-TI-N-EB has a hardened operating range of -40°C to +85°C, while EtherWAN lists the TC version as non-hardened with a 0°C to +70°C operating range. Both are listed for 70 km single-mode fiber operation at 1550 nm with duplex LC connectors.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003ch3 itemprop=\"name\"\u003eIs Coremicro an authorized EtherWAN dealer?\u003c\/h3\u003e\n      \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cp itemprop=\"text\"\u003eCoremicro displays an Authorized Dealer designation on its listing for this EtherWAN product. Contact Coremicro to verify current authorization status, manufacturer warranty terms and availability.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- FAQPAGE STRUCTURED DATA --\u003e\n  \u003cscript type=\"application\/ld+json\"\u003e\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n      {\n        \"@type\": \"Question\",\n        \"name\": \"What is the EtherWAN EX-LS48-C3U-TI-N-EB used for?\",\n        \"acceptedAnswer\": {\n          \"@type\": \"Answer\",\n          \"text\": \"The EtherWAN EX-LS48-C3U-TI-N-EB is a hardened Gigabit SFP transceiver for links over 9\/125 µm single-mode fiber. It has a rated reach of 70 km and a duplex LC optical connector.\"\n        }\n      },\n      {\n        \"@type\": \"Question\",\n        \"name\": \"How far can this EtherWAN Gigabit SFP transmit?\",\n        \"acceptedAnswer\": {\n          \"@type\": \"Answer\",\n          \"text\": \"This EtherWAN Gigabit SFP is rated for a 70 km fiber distance. Actual reach depends on fiber attenuation, connector and splice losses, and the available 23 dB link budget.\"\n        }\n      },\n      {\n        \"@type\": \"Question\",\n        \"name\": \"Does this SFP module support optical diagnostics?\",\n        \"acceptedAnswer\": {\n          \"@type\": \"Answer\",\n          \"text\": \"This SFP module supports Digital Diagnostic Monitoring (DDM). The available readings depend on the capabilities of the compatible host equipment.\"\n        }\n      },\n      {\n        \"@type\": \"Question\",\n        \"name\": \"Which fiber and wavelength does the module use?\",\n        \"acceptedAnswer\": {\n          \"@type\": \"Answer\",\n          \"text\": \"The module uses 9\/125 µm single-mode fiber with a duplex LC interface and a 1550 nm wavelength. The far-end transceiver must be compatible with the planned optical link.\"\n        }\n      },\n      {\n        \"@type\": \"Question\",\n        \"name\": \"Can this hardened SFP work in any Gigabit Ethernet switch?\",\n        \"acceptedAnswer\": {\n          \"@type\": \"Answer\",\n          \"text\": \"This hardened SFP requires a host that supports the module's optical and electrical specifications. Check the switch manufacturer's transceiver compatibility guidance before purchase.\"\n        }\n      },\n      {\n        \"@type\": \"Question\",\n        \"name\": \"What is the difference between the EX-LS48-C3U-TI-N-EB and EX-LS48-C3U-TC-N-EB?\",\n        \"acceptedAnswer\": {\n          \"@type\": \"Answer\",\n          \"text\": \"The EX-LS48-C3U-TI-N-EB has a hardened operating range of -40°C to +85°C, while EtherWAN lists the TC version as non-hardened with a 0°C to +70°C operating range. Both are listed for 70 km single-mode fiber operation at 1550 nm with duplex LC connectors.\"\n        }\n      },\n      {\n        \"@type\": \"Question\",\n        \"name\": \"Is Coremicro an authorized EtherWAN dealer?\",\n        \"acceptedAnswer\": {\n          \"@type\": \"Answer\",\n          \"text\": \"Coremicro displays an Authorized Dealer designation on its listing for this EtherWAN product. Contact Coremicro to verify current authorization status, manufacturer warranty terms and availability.\"\n        }\n      }\n    ]\n  }\n  \u003c\/script\u003e\n\n  \u003c!-- CTA --\u003e\n  \u003cdiv class=\"cm-cta\"\u003e\n    \u003ch3 class=\"cm-cta__title\"\u003e\n      Confirm Your EtherWAN Fiber Module Compatibility\n    \u003c\/h3\u003e\n    \u003cp class=\"cm-cta__text\"\u003e\n      Coremicro lists this EtherWAN hardened SFP with an Authorized Dealer designation. Contact the team to confirm the correct host switch, matching 1550 nm optic, optical budget and current product availability before ordering.\n    \u003c\/p\u003e\n    \u003ca href=\"\/pages\/contact\" class=\"cm-cta__button\"\u003e\n      Talk to a Specialist\n    \u003c\/a\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- FOOTER LINKS --\u003e\n  \u003cdiv class=\"cm-footer-links\"\u003e\n    \u003cp class=\"cm-footer-links__label\"\u003eContinue Exploring\u003c\/p\u003e\n    \u003cdiv class=\"cm-footer-links__list\"\u003e\n      \u003ca href=\"\/collections\/network\" class=\"cm-footer-links__item cm-footer-links__item--primary\"\u003e\n        Network Equipment\n      \u003c\/a\u003e\n      \u003ca href=\"\/products\/etherwan-sfpgzs20m-hardened-bidi-sfp\" class=\"cm-footer-links__item\"\u003e\n        EtherWAN 20 km BiDi SFP\n      \u003c\/a\u003e\n      \u003ca href=\"\/pages\/contact\" class=\"cm-footer-links__item\"\u003e\n        Contact Us\n      \u003c\/a\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n","brand":"EtherWan","offers":[{"title":"Default Title","offer_id":47488737542306,"sku":"EtherWan-EX-LS48-C3U-TI-N-EB","price":858.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/0860\/0738\/files\/EtherWan-EX-LS48-C3U-TI-N-EB_196c8593-bc76-4e2d-bcd9-6c9289e02b43.webp?v=1793068452","url":"https:\/\/www.coremicro.com\/products\/etherwan-ex-ls48-c3u-ti-n-eb-70km-sfp-module","provider":"COREMICRO.COM","version":"1.0","type":"link"}